1.
Rev. chil. obstet. ginecol ; 80(5): 412-415, ago. 2015. ilus
Article in Spanish | LILACS | ID: lil-764073

ABSTRACT

Se presenta el caso clínico de un dispositivo intrauterino parcialmente migrado a cavidad pélvica e incrustado en serosa de rectosigmoides luego de 8 años de su inserción. El diagnóstico se realizó mediante ecografía transvaginal y retiro del dispositivo por laparoscopia. Se realizó rafia de serosa rectal y de útero. La paciente tuvo un postoperatorio sin complicaciones.


It is shown the clinical case of an intrauterine device partially migrated to the pelvic cavity and embedded in the serous rectosigmoid eight years after insertion. The diagnosis was made by transvaginal ultrasound and laparoscopy removal of the device by laparoscopy. Suture of rectum serous and uterus were performed. The patient had an uneventful postoperative course.


Subject(s)
Humans , Female , Adult , Foreign-Body Migration/diagnostic imaging , Intrauterine Device Migration/adverse effects , Rectum/surgery , Rectum/injuries , Serous Membrane , Colon, Sigmoid/surgery , Colon, Sigmoid/injuries , Foreign-Body Migration/surgery , Ultrasonography , Laparoscopy , Device Removal